Instruction
Manual
Instruction Manual
Total Construction Solutions
PENTAX Industrial Instruments Co.,Ltd.
2-5-2 Higashi-Oizumi / Nerima-ku,Tokyo 178-0063,Japan
Tel.+81 3 5905 1222 / Fax +81 3 5905 1225
Website: www.pentax.co.jp/piic/survey
www.pentaxsurveying.com
PLP-601
PLP-602
PLP-601R
Automatic Self-leveling Laser
Automatic Self-leveling Laser
Automatic Self-leveling Laser
PLP-602R
Automatic Self-leveling Laser
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - Instruction

InstructionManualInstruction ManualTotal Construction SolutionsPENTAX Industrial Instruments Co.,Ltd.2-5-2 Higashi-Oizumi / Nerima-ku,Tokyo 178-0063,J

Strany 2

10CONTENTSafety PrecautionsPrecautions• 1. For proper use of the instrument 111.1 Standard configuration1.2 Description1.3 Unpacking1.4 Battery

Strany 3 - Distinctive Displays

111. For proper use of the instrument1.1 Standard configurationThe instrument (PLP-601 / PLP-602 /PLP-601R / PLP-602R)Detector (LS6)Rod Adapter (LA6)D

Strany 4

1.2 Description12Center markTop handleEmitting beam apertureKeypadDetachable knob for RotorBattery capBottom plate

Strany 5 - Precautions

13Plate VialBeam Reception WindowLCD DisplayIllumination Switch Buzzer Switch Accuracy Switch Power Switch IndexFixing KnobDetector Attaching Scr

Strany 6

141.3 UnpackingTaking the instrument out of the carrying caseGently set down the carrying case so that its cover is upward.Unlatch and open the case w

Strany 7

151.4 Battery insertionBattery insertion for the instrumentTurn the detaching knob for battery cap counterclockwise and remove the cap from the instru

Strany 8

16Battery insertion for the detectorLS6 DetectorSlide the battery cover while pushing its mark and remove it.Insert the accumulated dry battery

Strany 9

172.Display and Keypad2.1 Keypad2.2 Role of keys(1) Power supply key ONONOFFOFFBATTERY CHECK POWEROFFLEVELMANUALMODEBattery check keyRemaining battery

Strany 10

18(2) Battery check key Remaining battery display lamp NOTE:• When 4 pcs rechargeable batteries type D are used,only 2 green lamps are turned on even

Strany 11 - 1.1 Standard configuration

19(3) Auto/manual change keyNOTE:• Simple grade setting can be done by manual mode,but usually performed without stopping the automatic self-leveling

Strany 13 - Rod Adapter LA6

20(4) Switching the rotation speed• Please switch the rotation speed after turning off the instrument power supply.[From 300 to 600 rpm]NOTE:• When th

Strany 14 - 1.3 Unpacking

2.3 Warning displayOff level display lamp turns on in red as warning display and rotation ofrotor and emission of laser beam stop under following situ

Strany 15 - 1.4 Battery insertion

223. Preparation for measurement1.1 Setting up the tripod[Arranging the tripod]Prepare the normal tripod for Level instrument.The dome head type and e

Strany 16 - Rear View of LS6

23[Setting up the tripod]For an extension tripod,adjust the legs to a suitable length and secure the leg clamps.Spread the legs to a proper extent for

Strany 17 - 2.Display and Keypad

243.2 Setting up the instrument[Mounting on the tripod]Mount the instrument on the tripod head and while supporting the instrument with one hand,secur

Strany 18

253.3 Arranging the detector[Installing the rod adapter LA6]LS6 detectorMount the instrument on the rod adapter so that the guide pin of the rod adapt

Strany 19 - Auto/manual change key

264. Measurement4.1 Operating the instrument[Starting the operation]Press the power supply key.Automatic self-leveling function works and leveling beg

Strany 20

274.2 Operating the detector:LS6[Power switch]Push the power switch to turn on the power to the detector.Pushing the power switch again turns off the

Strany 21 - 2.3 Warning display

28[Selecting the reference level detecting accuracy]Push the detection accuracy selection switch to select the needed detection accuracy.High accuracy

Strany 22 - 1.1 Setting up the tripod

29[ON or OFF of the beam reception buzzer]Push the beam reception buzzer switch to select either the buzzer sounding or silenced.[Illuminating the dis

Strany 23

3Safety Precautions (must be followed)The following items are intended to prevent possible injury to the user orother people and/or damage to the inst

Strany 24 - 3.2 Setting up the instrument

30[Detecting the reference level]At the measuring point,set the position of the detector nearly to the height of the beam emitting aperture of the ins

Strany 25 - 3.3 Arranging the detector

31[Direct marking]After the reference level has been detected,mark a line along the detector’s index,or its top or bottom end.[Plain rod marking]After

Strany 26 - 4. Measurement

32[Reading the staff]After the reference level has been detected,read the staff,using the index on the rod adapter.NOTE:• When detecting the reference

Strany 27

335. Maintenance5.1 Maintenance after use[Stains on the main body]Brush dust off and wipe off moisture with tissue paper.Clean off any stains with a s

Strany 28 - Low accuracy

34[Handling the battery]If the instrument is not to be used for a long time,be sure to remove the batteries from the instrument and the detector and s

Strany 29

355.2 Check and adjustment of the datum point [Check]Set up the instrument on the tripod halfway between two walls or pillars about 40m away so that t

Strany 30

36Read the target plates on the walls (A,B) to detect the reference points.If the readings of the target plates differ less than ± 5 mm,the instrument

Strany 31

375.3 Troubleshooting PLP-601 / PLP-602 / PLP-601R / PLP-602RRotor Display Content Checking pointDisplay lamps are Battery capacity Replace with fres

Strany 32 - Rod Adapter

38Detector LS6Rotor Display Content Checking pointCan rotate Cannot detect Battery capacity Replace with freshis low. battery.Incorrect battery Check

Strany 33 - 5. Maintenance

396. SpecificationsINSTRUMENT PLP-601R / PLP-602RAccuracy of reference beam: ± 10”(PLP-601/PLP-601R)± 12”(PLP-602/PLP-602R)Measuring range: Radius 1~2

Strany 34

4WARNING• While the instrument is operating,be careful not to expose your eyes to the emitting laser beam (red light source).Exposure to a laser beam

Strany 35 - (Keypad)

407. Notice to the user of this productTo assure compliance with the Safety Standard 21 CFR,Chapter I.Subchapter J.The U.S.bureau of Radiological Heal

Strany 39 - 6. Specifications

Japan Surveying Instruments Manufacturers’ AssociationMember symbol of the Japan Surveying Instruments Manufacturers’Association representing the high

Strany 40

5PrecautionsThe instrument should not be stored or used in extreme temperatures orjob on a place subject to rapid change of temperature.(Refer to the

Strany 41

6Put into the carrying for storage and place in a dry area not subject to vibration,dust or high moisture.When storage and usage temperatures are wide

Strany 42

7The detector (option) may react to the Laser beam and further react to the Fluorescent lamp,Site lamp,modulated light or an electric wave (in or near

Strany 43

8The instrument should be stored in the carrying case and packed with cushioning material and handled with care as ‘Fragile’.Check the ‘check and adju

Strany 44 - Printed in Belgium

9Be sure to observe the items in the instruction manual for proper use of the instrument.Please replace attached batteries with new ones before you wo